Contact angle analysis
Home > Equipment > Testing and validation > Contact angle analysis
Contact angle analysis

Observing the contact angle of a liquid on a samples surface can be a simple way of determining a samples hydrophobicity. To measure this many contact angle analysers use a high resolution camera to take an image, then use specific software to interpret the photo and provide the angle of contact. It is often used in conjunction with other surface analysis techniques to paint a complete picture of surface behaviour based on a sample’s surface chemistry and roughness.

List of available equipment
TOOL MAKE AND MODEL
KEY DIFFERENTIATOR
LOCATION
Contact Angle System- OCA 20- DataPhysics
Contact angle of static and dynamic liquids
SA Node University of South Australia
Description
Optical contact angle measurement and drop contour analysis
Related Information
The drop is viewed in profile during the contact angle measurement.
Tool Contact
Simon.Doe@unisa.edu.au
Tensionmeter DataPhysics OCA-20
Optical contact angle analyser
University of Melbourne VIC Node
Description
Video-based contact angle measurement.
Related Information
Maximum sample size (L x W x H): 220 x ∞ x 70 mm, 8-inch wafer on WT 200M/E.Size of sample stage: 100 x 100 mmRange of contact angle: 0 - 180°, ±0.1° measuring accuracy of the video system
Tool Contact
elena.taran@unimelb.edu.au
Wilhelmy Balance- DCAT- DataPhysics
Dynamic contact angle measuring instrument
SA Node University of South Australia
Description
Dynamic contact angle measuring instrument and tensiometer
Related Information
Dynamic measurement of surface/interfacial tension
Tool Contact
Simon.Doe@unisa.edu.au
TOOL MAKE AND MODEL
KEY DIFFERENTIATOR
LOCATION
Contact Angle System- OCA 20- DataPhysics
Contact angle of static and dynamic liquids
SA Node University of South Australia
Description
Optical contact angle measurement and drop contour analysis
Related Information
The drop is viewed in profile during the contact angle measurement.
Tool Contact
Simon.Doe@unisa.edu.au
TOOL MAKE AND MODEL
KEY DIFFERENTIATOR
LOCATION
Tensionmeter DataPhysics OCA-20
Optical contact angle analyser
SA Node University of South Australia
Description
Video-based contact angle measurement.
Related Information
Maximum sample size (L x W x H): 220 x ∞ x 70 mm, 8-inch wafer on WT 200M/E.Size of sample stage: 100 x 100 mmRange of contact angle: 0 - 180°, ±0.1° measuring accuracy of the video system
Tool Contact
elena.taran@unimelb.edu.au
TOOL MAKE AND MODEL
KEY DIFFERENTIATOR
LOCATION
Wilhelmy Balance- DCAT- DataPhysics
Dynamic contact angle measuring instrument
SA Node University of South Australia
Description
Dynamic contact angle measuring instrument and tensiometer
Related Information
Dynamic measurement of surface/interfacial tension
Tool Contact
Simon.Doe@unisa.edu.au